Lantronix UDS1100 / UDS1100-PoE

SPHINX in Europe
SE
  • AT
  • BE
  • DK
  • FR
  • DE
  • IE
  • IT
  • NL
  • ES
  • SE
  • CH
  • UK
Produktgrupper > Embedded Device Networking > Lantronix UDS1100 / UDS1100-PoE

Lantronix UDS1100 / UDS1100-PoE

External Device Servers

Lantronix UDS1100 / UDS1100-PoE
5395_13826.png
5395_13827.jpg
  • EgenskaperEgenskaper
  • BeskrivningBeskrivning
  • Further InformationFurther Information
  • PDFPDF
  • Network virtually any device in minutes
  • Access, monitor and control equipment over Ethernet
  • Replace dedicated PCs and/or modem lines with fast and reliable Ethernet networking
  • Configure quickly and easily via HTTP, DHCP, Telnet, serial or Lantronix DeviceInstaller utility
  • Supports RS232, RS422 and RS485 communications
  • Environmentally-friendly RoHS and WEEE compliant
  • Small enough to place almost anywhere
  • Features TruPort® Com port control technology
  • Power over Ethernet (PoE) model available
  • Meets the newest UL 864 9th Edition standards
Device networking is what powers M2M (machine to machine) communication. The UDS family of external device servers enables users to connect, manage and control just about any piece of equipment with a serial port from virtually anywhere over Ethernet or the Internet.

With the UDS1100, virtually any piece of equipment can be added to an Ethernet network in a matter of minutes! This single-port external device server is a quick, simple and inexpensive way to bring the advantages of remote management to equipment not currently connected to a network.

And with the UL 864 listing, fire and alarm panel equipment manufactures can easily add networking capabilities to their existing UL 864-listed products without the need to reapply to UL.

Extending Serial to Ethernet Communications Across the Globe

Our approach to network-enabling devices is transparent to your attached equipment and software so you won’t need to change the way you work. Using a method called serial tunneling, the UDS1100 encapsulates serial data into packets and transports it over Ethernet. Serial tunneling can be done in two ways:
  • Using Lantronix supplied Com Port Redirector software, Windows® device applications not designed for network communications are re-directed to communicate to devices connected to the UDS1100.
  • Connecting two UDS1100 device servers configured to automatically talk to each other over the network creates virtual serial to Ethernet connections that can extend serial communications across a facility or around the world.

The built-in web server enables users to access and configure the UDS1100 from a standard web browser.

Web pages enabling the UDS1100 to be customized for unique applications can be built using Lantronix development tools. On-board Flash memory provides room for future system software upgrades and maintenance-free, non-volatile web page storage.

Easy to Set Up and Use

The UDS1100 can be set up locally through its serial port, or remotely using Telnet or a web browser. The included DeviceInstaller Windows-based configuration software simplifies setup and provides an easy way to:
  • Assign IP & other network specific addresses
  • Load custom web pages
  • Enable web-based configuration of the device server
  • Ping or query the attached device(s) over the network
  • View specific device data files
  • Upgrade firmware


Modem Replacement

In modem emulation mode, the UDS is used to replace dial-up modems. The unit accepts modem AT commands on the serial port. It then establishes a network connection to the end device, leveraging network connections and bandwidth to eliminate dedicated modems and phone lines. The PoE version enables you to also take advantage of network connectivity in areas without power outlets. Total Com Port Control with TruPort Technology

Built into the included Com Port Redirector software, TruPort® technology enables Windows-based applications to access and control serial ports on the UDS1100 as if they were actually local PC serial ports. The application can monitor and set hardware pins on the UDS1100 serial ports as well as access serial buffers for total Com port control. This allows existing applications to seamlessly transition from controlling local devices to true remote monitoring and control of devices around the world.

ProdGrafik

Serial Interface

    Interface: Software-selectable RS232, RS422 or RS485 (2 and 4 wire support)
    Connectors: 1 DB25F DCE serial port
    Data Rates: Software-selectable baud rate from 300 to 230 KBaud


Serial Line Format

    Characters: 7 or 8 data bits
    Parity: odd, even, none
    Stop Bits: 1 or 2 Control


Flow Control

    Signals: CTS/RTS (Hardware)
    Flow Control: XON/XOFF (Software)


Network Interface

    Interface: 10Base-T/100Base-TX Ethernet port
    Software selectable Ethernet speed 10/100/Auto
    Software selectable Half/Full/Auto duplex
    Connectors: RJ45
    Standards: ARP, UDP, TCP, ICMP, Telnet, TFTP, AutoIP, DHCP, HTTP, SNMP TCP, UDP, and Telnet, TFTP


Indicators (LED)

    Power, 10/100 Link/Activity (green)
    100/100 Link/Activity (green)
    Diagnostics (red)
    Status (green)


Processor

    CPU: Lantronix DSTNI-EX 48 MHz clock
    Memory: 256 KB zero wait state SRAM, 2 MB Flash


Management

    Lantronix DeviceInstaller GUI, Serial login, SNMP, Telnet login, HTTP


Power

    9-30 VDC or 9-24 VAC on barrel connector (1.5 Watts maximum consumption)
    9-30 VDC on DB25F serial interface


Environmental

    Operating: 0° to 60° C (32° to 140°F)
    Storage: -40° to 85° C (-40° to 185° F)


Agency Approvals

    UL, CSA, FCC, CE, TUV, CTick, VCC, UL 864


Included Software

    Windows® 98/ME/NT/2000/XP-based DeviceInstaller configuration software, Com Port Redirector software and related utilities


Packaging

    Material: Metal enclosure with integrated wall mounts; optional 35 mm DIN-rail mount available
    Dimensions (LxWxH): 9.0 x 6.4 x 2.3 cm (3.5 x 2.5 x 0.9 in)
    Weight: 0.20 kg (0.45 lb)
    IP Rating: 30


Shipping Dimensions

    Dimensions (LxWxH): 35.5 x 17.1 x 7.6 cm (14 x 6.75 x 3 in)
    Weight: 1.5 kg (3.0 lbs)


Emissions


FCC Part 15 Subpart B Class A Radiated Emissions 30MHz – 1000MHz
ICES-003 Issue 4 February 2004 Class A Radiated Emissions 30MHz – 1000MHz
AS/NZS CISPR 22: 2004 Class A Radiated Emissions 30MHz – 1000MHz
EN55022: 1998 + A1: 2000 + A2: 2003 Class A Radiated Emissions 30MHz – 1000MHz
VCCI V-3/2005.04 Class A Radiated Emissions 30MHz – 1000MHz
EN61000-3-2: 2000 Class A Harmonic Current Emissions
EN61000-3-3: 1995 + A1: 2001 Fluctuations and Flicker


Immunity


EN55024: 1998 +A1: 2001 +A2: 2003
IEC_61000-4-2: 1995 ESD 8kV Air Discharge (Direct), 4kV Contact Discharge (Direct/Indirect)
IEC_61000-4-3: 1995 Radiated Immunity 3.0V/m, 1KHz AM Sine Wave at 80%
IEC_61000-4-4: 1995 EFT/Burst 1.0kV Power Lines, 0.5kV I/O Lines
IEC_61000-4-5: 1995 Surge Immunity 1.0kV Common Mode, 1.0 kV Differential Mode
IEC_61000-4-6: 1996 Conducted Immunity 3.0 Vrms, 80% AM Modulated (1KHz)
IEC_61000-4-8: 1993 Magnetic Field Immunity 50Hz 1.0 Arms/m
IEC_61000-4-11: 1994 Voltage Dips and Interrupts (>95%,0.5 periods), (30%,25 periods), (>95%,250 periods)


Isolation

  • Designed with protection against transients and ESD for use under harsh environments.
  • Serial Port: 15 kV ESD protection on RS232 and RS422/485 transceivers
  • Power Input: Up to non-repeated 600 W 10/100 usec pulse protection against transient over voltages
  • Ethernet Port: 1500 VAC isolation shielded with shield connected to chassis ground for signal integrity and ESD protection



Ordering Information
Available Models
Part Number Name Description
UD1100001-01 UDS1100 device server,
US domestic power 120 VAC power supply
RoHS
UD11000P0-01 UDS1100-PoE UDS1100-PoE device server