MOXA CP-602U-I Series

2-port CAN Interface Universal PCI board with 2 KV isolation

MOXA CP-602U-I Series
2668_12694.png
2668_8461.png
  • EgenskaperEgenskaper
  • BeskrivningBeskrivning
  • Further InformationFurther Information
  • PDFPDF
  • CAN 2 .0A and CAN 2.0B supported
  • Two independent CAN communication ports
  • CAN transfer rate up to 1 Mbps
  • 2 KV optical isolation protection
  • LED for transmit/receive status on each port
  • Optional 120 ohm terminal resistor for CAN bus network
  • DLL library and examples included
  • Windows driver provided
Moxa’s new CP-602U-I CAN (Controller Area Network) interface board supports the Universal PCI interface. As a stand-alone CAN controller, the CP-602U-I is a cost-effective solution that provides two active CAN controllers with a DB9 connector on the same board. The CP- 602U-I CAN interface board uses the NXP SJA1000 and transceiver PCA82C251, which provide the bus arbitration and error detection. The -40 to 85°C wide operating temperature (CP-602U-I-T only) and 2 KV isolation make the boards suitable for use in harsh industrial environments.
ProdGrafik

Hardware

Card Interface
Universal PCI

Connectors
DB9 male x 2

CAN Controller
NXP SJA1000

CAN Transceiver
PCA82C251

CAN Specification
CAN 2.0 A/B

Signal Support
CAN_H, CAN_L, GND

Transfer Rate
1 Mbps

Max. Number of Boards per PC
4

Electrical Isolation
2 kV

Termination Resistor
120 ohm (selected by jumper)


Driver Support

Operating Systems
Windows 2000, Windows XP/2003/Vista/2008 (x86/x64)

Linux Real TTY Drivers
Linux 2.6.x, 3.x


Software

Libraries
Visual C/C++, Borland C/C++


Environmental Limits

Operating Temperature
Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 85°C (-40 to 185°F)

Storage Temperature
-40 to 85°C (-40 to 185°F)

Ambient Relative Humidity
5 to 95% (non-condensing)

Altitude
Up to 2000 m
Note Please contact us if you require products guaranteed to function properly at higher altitudes.


Standards and Certifications

EMC
CE, FCC

EMI
EN 61000-3-2, EN 61000-3-3, FCC Part 15 Subpart B Class B

EMS
IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11 (DIPS)

Green Product
RoHS, CRoHS, WEEE


MTBF (mean time between failures)

Time
1,989,990 hrs

Database
Telcordia (Bellcore), GB


Power Requirements

Power Consumption
365 mA @ 5 VDC




Ordering Information
CP-602U-I: 2-port CAN interface Universal PCI board, with 2 KV isolation protection, 0 to 55°C operating temperature